FCF-RZF
Energy Saving Throughout the cooling season, Daikin’s new inverter models reduce energy consumption. Compared with previous non-inverter series, the new RZF-C series uses about 50% less power consumption for quick and effective cooling that reduces electricity bills.
|
|
From R410A to R32, Another step towards lower global warming potential
|
Use of new wide flaps (Straight)
With new, larger flaps, a straighter trajectory for airflow was achieved.
New wide flap construction inhabits ceiling dirt and grime.
By tapering both flap ends, the airflow that causes dirty ceiling is directed downward.
Increased velocity in 2-way flow (Strongly)
Velocity increased by making 2-way flow. Powerful airflow was realized.
* Other 2 outlets are controlled by changing the flap direction (angle) to suppress airflow volume.
Optimizing airflow angle (Horizontally)
The airflow angle was made more horizontal.
Comfortable air conditioning for all room layouts and conditions
Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution. Individual airflow settings.
No individual setting (Auto airflow)
- Position 0 (Highest point)
- Position 1
- Position 2
- Position 3
- Position 4 (Lowest point)
- Swing
Dual Sensors*2
Dual sensors and individual airflow direction control automatically provide optimal control of airflow.
Infrared Presence Sensor
The sensor detects the presence of people in each of the 4 areas.
Ceiling height |
2.7m |
3.5m |
4.0m |
Detection range (diameter)*³ |
approx. 8.5m |
approx. 11.5m |
approx. 13.5m |
Infrared floor sensor
The sensor detects the floor temperature and automatically adjusts operation of the indoor unit to reduce temperature difference between the ceiling and the floor.
Ceiling height |
2.7m |
3.5m |
4.0m |
Detection range (diameter)*³ |
approx. 8.5m |
approx. 11.5m |
approx. 13.5m |
Auto airflow function
With “Auto” airflow direction mode, flaps are controlled to deliver optimal airflow when the room is unoccupied.
Auto airflow function
When presence is detected, air direction is set to “Swing (narrow)” to deliver cool air to users.
Over voltage PCB (Outdoor unit option) |
Outdoor unit installation is possible even with limited space |
Microchannel heat exchanger |
Automatic protection against low voltage |
Coated printed circuit boards (outdoor unit) |
Self diagnosis functions enable prompt maintenance response |
Navigation remote controller BRC1E63 includes various convenient functions |
|||
Automatic return to temperature preset by owner.
|
|
Owner can preset upper and lower temperatures.
|
CONVENIENT FUNCTIONS |
Demand control function
By setting limits that restrict power consumption, you can cut electricity bills.
Power consumption is given first priority, and limits maximum power consumption of unit.
Maximum power consumption can be set at 40, 60, 70, 80, or 100%.
CONVENIENT FUNCTIONS |
Night quiet operation mode
Consideration is given for people living nearby.
Outdoor unit operation sound can be reduced.
CEILING MOUNTED CASSETTE TYPE (1 Phase) |
|
50 |
60 |
71 |
100 |
125 |
140 |
||
Model Name |
Indoor Unit |
|
FCF50CVM |
FCF60CVM |
FCF71CVM |
FCF100CVM |
FCF125CVM |
FCF140CVM |
Outdoor Unit |
|
RZF50CVM |
RZF60CVM |
RZF71CVM |
RZF100CVM |
RZF125CVM |
RZF140CVM |
|
Power Supply |
Outdoor Unit |
1 phase, 220-240V, 50Hz |
||||||
Cooling Capacity Rated (Min. - Max.) |
Rated (Min - Max) |
kW |
5.0 (3.2-5.6) |
6.0 (3.2-6.0) |
7.1 (3.2-8.0) |
10.0 (5.0-11.2) |
11.5 (5.7-14.0) |
14.0 (6.2-15.5) |
Btu/h |
24,200 (10,900-27,300) |
24,200 (10,900-27,300) |
24,200 (10,900-27,300) |
34,100 (17,100-38,200) |
42,700 (19,500-47,800) |
47,800 (21,100-52,900) |
||
Power consumption |
Cooling |
kW |
1.14 |
1.53 |
1.93 |
2.97 |
4.18 |
5.47 |
COP |
W/W |
4.39 |
3.92 |
3.68 |
3.37 |
2.99 |
2.56 |
|
CSPF |
Wh/Wh |
6.60 |
6. |
6.17 |
5.50 |
5.15 |
5.00 |
CEILING MOUNTED CASSETTE TYPE (3 Phase) |
|
71 |
100 |
125 |
140 |
||
Model Name |
Indoor Unit |
|
FCF71CVM |
FCF100CVM |
FCF125CVM |
FCF140CVM |
Outdoor Unit |
|
RZF71CYM |
RZF100CYM |
RZF125CYM |
RZF140CYM |
|
Power Supply |
Outdoor Unit |
3 phase, 380-415V, 50Hz |
||||
Cooling Capacity Rated (Min. - Max.) |
Rated (Min - Max) |
kW |
7.1 (3.2-8.0) |
10.0 (5.0-11.2) |
11.5 (5.7-14.0) |
14.0 (6.2-15.5) |
Btu/h |
24,200 (10,900-27,300) |
34,100 (17,100-38,200) |
42,700 (19,500-47,800) |
47,800 (21,100-52,900) |
||
Power consumption |
Cooling |
kW |
1.93 |
2.97 |
4.18 |
5.47 |
COP |
W/W |
3.68 |
3.37 |
2.99 |
2.56 |
|
CSPF |
Wh/Wh |
6.17 |
5.50 |
5.15 |
5.00 |